Nova Scotia solar label kits
Nova Scotia Power's Bulletin B-64-200 took effect 2 July 2024 and its wording is what its inspectors expect in NSPI territory. It also changed the DC conductor warning, which many catalogues still engrave the old way.
278 square inches of engraved. Microinverters are 17 plates.
Including 4 that exist nowhere in the national base set.
Plates engraved to the previous revision carry the old DC warning.
The sentence that changed
The DC conductor warning now reads “DC CONDUCTORS MAY BE ENERGIZED”. The words “Ungrounded and” were removed from the front of it. Our Nova Scotia set adds a plate with that wording for the exterior DC disconnecting means and DC transition boxes; in NSPI territory the utility's wording is what its inspectors expect.
Four plates that exist only here
Nova Scotia Power asks for plates that are not in the national base set. Two of them depend on how the job is built, so they are questions in the builder rather than automatic.
| Plate & rule | Where it goes |
|---|---|
| Maximum inverter output NSP B-64-200 p.1 (inspection-authority requirement) | On or adjacent to the inverter and the main AC disconnect switch. Where micro-inverters are used, required only on the main AC disconnect. Applies to DC string inverter systems. |
| Generator transfer switch caution NSP B-64-200 p.6 (inspection-authority requirement) | At the transfer switch location. |
| Solar panelboard on dual-lug meter base NSP B-64-200 p.6-7 (with 64-112(2)) | On a solar panelboard connected to a dual lug meter base. |
| NSP DC conductors may be energized 64-068(1)(b) / 64-066(7) (NSP B-64-200 wording) | Exterior DC disconnecting means and DC transition boxes. |
The inverter output plate
NSPI wants the maximum inverter output stated in amps, on or adjacent to the inverter and the main AC disconnect. On a microinverter job it is required only on the main AC disconnect. It carries a number off your design, so it cannot be stocked. Tell us the figure or send the single-line and we will read it off.
Standby generators
If there is a transfer switch on site, NSPI wants a caution plate at it. That is a separate question in the builder because plenty of Nova Scotia solar jobs have a generator already installed and plenty do not.
278 square inches against Ontario's 287 for the same house kit. NSPI's published wording is shorter than the generic text it replaces, so several plates come down a size. Published wording does not always cost more. Saskatchewan's does. This one doesn't.
The bulletin governs where Nova Scotia Power distributes. For a job on another system, the CEC base set applies and the inspector settles wording.
Nova Scotia kits
| Job | Plates here | Ontario |
|---|---|---|
| House, string inverter | 22 | 21 |
| House, microinverters | 17 | 17 |
| House with battery | 26 | 25 |
| Commercial rooftop | 31 | 30 |
| Ground mount / solar farm | 33 | 32 |
| Off-grid / cabin | 17 | 16 |
| Re-label an existing install | 9 | 8 |